AM803x & AM853x

Electrical data

AM80xx and AM85xx

31C

31D

31F

32D

32E

  • Standstill torque M0 [Nm]

1.37

1.38

1.40

2.38

2.37

  • Standstill current Iorms [A]

1

1.95

3.20

1.70

2.95

  • Maximum mechanical speed Nmax [min-1]

10000

  • Maximum nominal mains voltage UN [VAC]

480

  • Peak current I0max [A]

5.50

10.70

17.60

9.60

17.20

  • Peak torque M0max [Nm]

6.10

6.07

6.07

11.66

11.66

  • Torque constant KTrms [Nm/A]

1.37

0.71

0.44

1.40

0.80

  • Voltage constant KErms [mVmin]

99

50

30

100

56

  • Winding resistance Ph-Ph R20 [Ω]

51

12.60

5

21

6.50

  • Winding inductance Ph-Ph, measured at 1 kHz L [mH]

134

36

13.30

71.90

22.60

Power supply UN= 115 V

  • Nominal speed Nn [min-1]

400

1400

2700

600

1400

  • Nominal torque Mn [Nm]

1.36

1.38

1.37

2.37

2.34

  • Nominal output Pn [kW]

0.06

0.20

0.39

0.15

0.34

Power supply UN= 230 V

  • Nominal speed Nn [min-1]

1400

3300

6000

1500

3000

  • Nominal torque Mn [Nm]

1.35

1.36

1.34

2.34

2.30

  • Nominal output Pn [kW]

0.20

0.47

0.84

0.37

0.76

Power supply UN= 400 V

  • Nominal speed Nn [min-1]

3000

6000

9000

3000

6000

  • Nominal torque Mn [Nm]

1.34

1.33

1.30

2.30

2.20

  • Nominal output Pn [kW]

0.42

0.84

1.23

0.72

1.38

  • Nominal current In [A]

0.95

1.90

3

1.60

2.75

Power supply UN= 480 V

  • Nominal speed Nn [min-1]

3400

6800

9000

3400

6800

  • Nominal torque Mn [Nm]

1.33

1.32

1.30

2.26

2.10

  • Nominal output Pn [kW]

0.47

0.94

1.23

0.80

1.50

Connection technology

iTec

Reference flange aluminum 230 mm x 130 mm x 10 mm

Electrical data

AM80xx and AM85xx

32H

33E

33F

33J

  • Standstill torque M0 [Nm]

2.37

3.20

3.22

3.22

  • Standstill current Iorms [A]

5.10

2.10

4.10

6.80

  • Maximum mechanical speed Nmax [min-1]

10000

  • Maximum nominal mains voltage UN [VAC]

480

  • Peak current I0max [A]

29.50

12.90

24.60

39.80

  • Peak torque M0max [Nm]

11.65

17.19

17.71

17.22

  • Torque constant KTrms [Nm/A]

0.46

1.52

0.78

0.47

  • Voltage constant KErms [mVmin]

32

106

57

34

  • Winding resistance Ph-Ph R20 [Ω]

2.20

13.20

3.90

1.35

  • Winding inductance Ph-Ph, measured at 1 kHz L [mH]

7.70

46.30

14

4.90

Power supply UN= 115 V

  • Nominal speed Nn [min-1]

2700

600

1400

2700

  • Nominal torque Mn [Nm]

2.29

3.15

3.10

3.05

  • Nominal output Pn [kW]

0.65

0.20

0.45

0.86

Power supply UN= 230 V

  • Nominal speed Nn [min-1]

6000

1500

3000

5900

  • Nominal torque Mn [Nm]

2.10

3.10

3

2.70

  • Nominal output Pn [kW]

1.32

0.49

1

1.67

Power supply UN= 400 V

  • Nominal speed Nn [min-1]

9000

3000

6000

9000

  • Nominal torque Mn [Nm]

1.85

2.98

2.70

2.30

  • Nominal output Pn [kW]

1.74

0.94

1.70

2.17

  • Nominal current In [A]

4.10

2

3.60

5.10

Power supply UN= 480 V

  • Nominal speed Nn [min-1]

9000

3400

6800

9000

  • Nominal torque Mn [Nm]

1.85

2.95

2.60

2.30

  • Nominal output Pn [kW]

1.74

1.05

1.85

2.17

Connection technology

iTec

Reference flange aluminum 230 mm x 130 mm x 10 mm

Mechanical data

AM8031

AM8531

AM8032

AM8532

AM8033

AM8533

  • Rotor moment of inertia J [kgcm2]

0.47

1.67

0.85

2.05

1.23

2.44

  • Rotor moment of inertia with brake J [kgcm2]

0.55

1.76

0.93

2.15

1.46

---

  • Number of poles

8

  • Static friction torque MR [Nm]

0.01

0.01

0.02

0.02

0.02

0.02

  • Thermal time constant tTH [min]

24

24

26

26

28

28

  • Weight [kg]

1.80

2.40

2.40

3

3

3.60

  • Weight with brake [kg]

2.20

2.60

2.80

3.30

3.60

---

Flange

IEC standard/DIN 42955

  • Fit

j6

  • Tolerance class

N

Protection rating

  • Standard housing version

IP65

  • Standard shaft feedthrough version

IP54

  • Shaft feedthrough with shaft sealing ring

IP65

Paint finishes

  • Properties

acrylic powder-coated

  • Color

Anthracite gray; RAL 7016

Optional holding brake [+]

AM8031

AM8531

AM8032

AM8532

AM8033

  • Holding torque at 120 °C MBR [Nm]

2

3.5

  • Supply voltage UBR [VDC]

24; +6 % to -10 %

  • Electrical power PBR [W]

11

12

  • Current Ion [A]

0.33

0.36

  • Release delay time tBRH [ms]

25

35

  • Application delay time tBRL [ms]

8

15