Feedback

Feedback 1:

Feedback exchange

The feedback system installed can only be replaced with an identical system. It is not possible to change the feedback system retrospectively. The feedback may only be exchanged by Beckhoff service.

The table below provides information about system accuracies and resolutions of the motor feedback systems:

Feedback

Resolution

System accuracy

Comment

OCT, single-turn

OCT, multi-turn

18-bit

± 120 angular seconds ~ 0.03°

Standard:

AM801x – AM8x6x

Standard fan:

AM805x – AM8x6x

Hiperface, single-turn

Hiperface, multi-turn

18-bit

± 120 angular seconds ~ 0.03°

Standard:

AM807x

OCT, single-turn

OCT, multi-turn

23-bit

± 45 angular seconds ~ 0.0125°

From firmware v2.10

OCT, single-turn

OCT, multi-turn

24-bit

± 25 angular seconds ~ 0.0069°

SIL 2

From firmware v2.10

Resolver

14-bit

± 600 angular seconds ~ 0.17°

Option