NPS025 MA

Mechanical data

1-stage

2-stage

  • Ratio

3

4

9

12

15

16

20

28

30

40

  • Efficiency under full load ŋ [%]

97

95

  • Running noise LPA [dB]
  • at n1 = 3000 rpm without load

≤ 61

≤ 59

  • Service life Lh [h]

> 20000

  • Weight [kg]
  • Depending on the clamping hub diameter and selected adapter plate

3.6

3.9

Mass moment of inertia J1 [kgcm²]

  • Based on the drive
  • Letters = specification of the clamping hub diameter
  • A = 9 mm

---

---

0.26

0.22

0.21

0.21

0.2

0.19

0.19

0.19

  • B = 11 mm

---

---

0.28

0.24

0.23

0.23

0.22

0.21

0.21

0.21

  • C = 14 mm

0.58

0.47

0.35

0.31

0.3

0.3

0.3

0.29

0.28

0.28

  • D = 16 mm

0.73

0.62

0.48

0.44

0.43

0.43

0.42

0.41

0.41

0.41

  • E = 19 mm

0.81

0.71

0.56

0.52

0.51

0.52

0.51

0.5

0.5

0.49

  • G = 24 mm

1.8

1.7

---

---

---

---

---

---

---

---

  • H = 28 mm

1.6

1.4

---

---

---

---

---

---

---

---

Torques and speeds

  • Maximum torque T2a [Nm]

185

  • Maximum acceleration torque T2B [Nm]
  • Maximum 1000 cycles per hour

125

115

125

125

120

115

115

115

105

115

  • EMERGENCY STOP torque T2Em.stop [Nm]
  • Possible 1000 times during the service life of the gear unit

190

  • Nominal input speed n1N [min-1]

2700

2900

2900

3500

3700

3500

3700

4000

4300

4300

  • Maximum input speed n1Max [min-1]

7000

7000

8000

8000

8000

8000

8000

8000

8000

8000

  • Idle torque T012 [Nm]
  • Based on the drive

1.8

1.5

0.67

0.55

0.47

0.46

0.4

0.34

0.33

0.29

Torsion and forces

  • Maximum torsional backlash jt [arcmin]

Standard ≤ 8

Standard ≤ 10

  • Maximum torsional rigidity Ct21 [arcmin]

12

  • Maximum axial force F2AMax [N]
  • In relation to the shaft center at the output

3350

  • Maximum lateral force F2QMax [N]
  • In relation to the shaft center at the output

4200

  • Maximum breakdown torque M2Max [Nm]

236

Temperature [°C]

  • Maximum housing temperature

+ 90

  • Ambient temperature

-15 to +40

Housing

  • Properties

Heat-treated steel

  • Color

Anthracite gray; RAL 7016

  • Seal

Sealed bearing disks