TP300 MF

Mechanical data

1-stage

  • Ratio

5

7

8

10

  • Efficiency under full load ŋ [%]

95

  • Running noise LPA [dB]
  • at n1 = 3000 rpm without load

≤ 64

  • Service life Lh [h]

> 20000

  • Weight [kg]
  • Depending on the clamping hub diameter and selected adapter plate

60

Mass moment of inertia J1 [kgcm²]

  • Based on the drive
  • Letters = specification of the clamping hub diameter
  • N = 55 mm

82.5

61.2

61.2

49.5

Torques and speeds

  • Maximum torque T2a [Nm]

5600

5250

2800

2800

  • Nominal output torque T2N [Nm]
  • At n1N

1996

1835

1815

1794

  • Maximum acceleration torque T2B [Nm]
  • Maximum 1000 cycles per hour

4200

3960

2280

2280

  • EMERGENCY STOP torque T2Em.stop [Nm]
  • Possible 1000 times during the service life of the gear unit

9900

9900

8557

8750

  • Nominal input speed n1N [min-1]

1000

1400

1400

1700

  • Maximum input speed n1Max [min-1]

3000

  • Idle torque T012 [Nm]
  • Based on the drive

20

14

14

8.8

Torsion and forces

  • Maximum torsional backlash jt [arcmin]

Standard ≤ 3 / Reduced ≤ 1

  • Maximum torsional rigidity Ct21 [arcmin]

1000

900

700

700

  • Maximum axial force F2AMax [N]
  • In relation to the shaft center at the output

33000

  • Maximum breakdown torque M2Max [Nm]

3900

  • Tilting rigidity C2K [Nm/arcmin]

5560

Temperature [°C]

  • Maximum housing temperature

+ 90

  • Ambient temperature

-15 to +40

Housing

  • Properties

Heat-treated steel

  • Color

Anthracite gray; RAL 7016

  • Seal

Sealed bearing disks

Mechanical data

2-stage

  • Ratio

20

21

25

31

32

35

50

61

  • Efficiency under full load ŋ [%]

94

  • Running noise LPA [dB]
  • at n1 = 3000 rpm without load

≤ 61

  • Service life Lh [h]

> 20000

  • Weight [kg]
  • Depending on the clamping hub diameter and selected adapter plate

58.5

Mass moment of inertia J1 [kgcm²]

  • Based on the drive
  • Letters = specification of the clamping hub diameter
  • M = 48 mm

27.5

27

25.9

25.6

22.4

22.4

21.5

21.4

Torques and speeds

  • Maximum torque T2a [Nm]

3850

3740

3949

3850

3630

3949

3600

3080

  • Nominal output torque T2N [Nm]
  • At n1N

1354

1456

1676

2114

2353

1710

1722

2070

  • Maximum acceleration torque T2B [Nm]
  • Maximum 1000 cycles per hour

3850

3740

3949

3850

3630

3949

3600

3080

  • EMERGENCY STOP torque T2Em.stop [Nm]
  • Possible 1000 times during the service life of the gear unit

9900

9870

9900

9156

9900

9900

9900

9900

  • Nominal input speed n1N [min-1]

2000

2000

2000

2000

2000

2000

2300

2400

  • Maximum input speed n1Max [min-1]

4375

  • Idle torque T012 [Nm]
  • Based on the drive

6.7

5.5

5.5

4.8

5.5

4

3.8

2.8

Torsion and forces

  • Maximum torsional backlash jt [arcmin]

Standard ≤ 3 / Reduced ≤ 1

  • Maximum torsional rigidity Ct21 [arcmin]

850

800

950

750

950

900

800

700

  • Maximum axial force F2AMax [N]
  • In relation to the shaft center at the output

33000

  • Maximum breakdown torque M2Max [Nm]

5900

  • Tilting rigidity C2K [Nm/arcmin]

5560

Temperature [°C]

  • Maximum housing temperature

+ 90

  • Ambient temperature

-15 to +40

Housing

  • Properties

Heat-treated steel

  • Color

Anthracite gray; RAL 7016

  • Seal

Sealed bearing disks

Mechanical data

2-stage

  • Ratio

64

70

91

100

  • Efficiency under full load ŋ [%]

94

  • Running noise LPA [dB]
  • at n1 = 3000 rpm without load

≤ 61

  • Service life Lh [h]

> 20000

  • Weight [kg]
  • Depending on the clamping hub diameter and selected adapter plate

58.5

Mass moment of inertia J1 [kgcm²]

  • Based on the drive
  • Letters = specification of the clamping hub diameter
  • M = 48 mm

25.8

21.3

21.2

21.2

Torques and speeds

  • Maximum torque T2a [Nm]

2800

3630

2800

2800

  • Nominal output torque T2N [Nm]
  • At n1N

2240

2339

2240

2240

  • Maximum acceleration torque T2B [Nm]
  • Maximum 1000 cycles per hour

2800

3630

2800

2800

  • EMERGENCY STOP torque T2Em.stop [Nm]
  • Possible 1000 times during the service life of the gear unit

9900

9900

8750

8750

  • Nominal input speed n1N [min-1]

2300

2400

2500

2500

  • Maximum input speed n1Max [min-1]

4375

  • Idle torque T012 [Nm]
  • Based on the drive

3.8

3

2.8

2.4

Torsion and forces

  • Maximum torsional backlash jt [arcmin]

Standard ≤ 3 / Reduced ≤ 1

  • Maximum torsional rigidity Ct21 [arcmin]

800

800

600

650

  • Maximum axial force F2AMax [N]
  • In relation to the shaft center at the output

33000

  • Maximum breakdown torque M2Max [Nm]

5900

  • Tilting rigidity C2K [Nm/arcmin]

5560

Temperature [°C]

  • Maximum housing temperature

+ 90

  • Ambient temperature

-15 to +40

Housing

  • Properties

Heat-treated steel

  • Color

Anthracite gray; RAL 7016

  • Seal

Sealed bearing disks