SP100 MF

Mechanical data

1-stage

  • Ratio

3

4

5

7

8

10

  • Efficiency under full load ŋ [%]

97

  • Running noise LPA [dB]
  • at n1 = 3000 rpm without load

≤ 58

  • Service life Lh [h]

> 20000

  • Weight [kg]
  • Depending on the clamping hub diameter and selected adapter plate

7.7

Mass moment of inertia J1 [kgcm²]

  • Based on the drive
  • Letters = specification of the clamping hub diameter
  • E = 19

3.29

2.35

1.92

1.60

1.38

  • G = 24

3.99

3.04

2.61

2.29

2.07

  • H = 28

3.59

2.65

2.22

1.90

1.68

  • K = 38

11.1

10.1

9.68

9.36

9.14

Torques and speeds

  • Rated torque at the output T2N [Nm]
  • at n1N

131

171

169

166

174

  • Maximum acceleration torque T2B [Nm]
  • Maximum 1000 cycles per hour

282

378

282

  • EMERGENCY STOP torque T2Emer [Nm]
  • Possible 1000 times during the service life of the gear unit

500

625

  • Nominal input speed n1N [min-1]

2500

2800

  • Maximum input speed n1Max [min-1]

5500

  • Idle torque T012 [Nm]
  • Based on the drive

3.10

2.40

2.10

1.30

1

Torsion and forces

  • Maximum torsional backlash jt [arcmin]

Standard ≤ 3 / Reduced ≤ 1

  • Maximum torsional rigidity Ct21 [arcmin]

31

  • Maximum axial force F2AMax [N]
  • In relation to the shaft center at the output

5650

  • Maximum lateral force F2QMax [N]
  • In relation to the shaft center at the output

6600

  • Maximum breakdown torque M2Max [Nm]

487

Temperature [°C]

  • Maximum housing temperature

+ 90

  • Ambient temperature

-15 to +40

Housing

  • Properties

Heat-treated steel

  • Color

Anthracite gray; RAL 7016

  • Seal

Sealed bearing discs

Mechanical data

2-stage

  • Ratio

16

20

25

28

32

35

40

50

64

70

100

  • Efficiency under full load ŋ [%]

94

  • Running noise LPA [dB]
  • at n1 = 3000 rpm without load

≤ 56

  • Service life Lh [h]

> 20000

  • Weight [kg]
  • Depending on the clamping hub diameter and selected adapter plate

7.9

Mass moment of inertia J1 [kgcm²]

  • Based on the drive
  • Letters = specification of the clamping hub diameter
  • C = 14 mm

0.64

0.54

0.52

0.43

0.38

0.54

0.37

  • E = 19 mm

0.81

0.70

0.68

0.60

0.43

0.59

0.55

0.54

0.38

0.54

  • G = 24 mm

2.18

2.07

2.05

1.97

1.96

1.92

1.91

  • H = 28 mm

1.98

1.90

1.88

1.81

1.80

1.76

1.75

Torques and speeds

  • Rated torque at the output T2N [Nm]
  • at n1N

243

259

257

277

243

277

207

277

207

  • Maximum acceleration torque T2B [Nm]
  • Maximum 1000 cycles per hour

347

259

347

259

  • EMERGENCY STOP torque T2Emer [Nm]
  • Possible 1000 times during the service life of the gear unit

625

  • Nominal input speed n1N [min-1]

3100

3500

4200

  • Maximum input speed n1Max [min-1]

6500

  • Idle torque T012 [Nm]
  • Based on the drive

1

0.93

0.85

0.77

0.86

0.54

0.46

0.39

0.37

Torsion and forces

  • Maximum torsional backlash jt [arcmin]

Standard ≤ 5 / Reduced ≤ 3

  • Maximum torsional rigidity Ct21 [arcmin]

31

  • Maximum axial force F2AMax [N]
  • In relation to the shaft center at the output

5650

  • Maximum lateral force F2QMax [N]
  • In relation to the shaft center at the output

6600

  • Maximum breakdown torque M2Max [Nm]

487

Temperature [°C]

  • Maximum housing temperature

+ 90

  • Ambient temperature

-15 to +40

Housing

  • Properties

Heat-treated steel

  • Color

Anthracite gray; RAL 7016

  • Seal

Sealed bearing discs