SP060 MF

Mechanical data

1-stage

  • Ratio

3

4

5

7

8

10

  • Efficiency under full load ŋ [%]

97

  • Running noise LPA [dB]
  • at n1 = 3000 rpm without load

≤ 58

  • Service life Lh [h]

> 20000

  • Weight [kg]
  • Depending on the clamping hub diameter and selected adapter plate

1.9

Mass moment of inertia J1 [kgcm²]

  • Based on the drive
  • Letters = specification of the clamping hub diameter
  • B = 11 mm

0.21

0.15

0.12

0.10

0.09

  • C = 14 mm

0.28

0.22

0.20

0.18

0.16

  • E = 19 mm

0.61

0.55

0.52

0.50

0.49

Torques and speeds

  • Rated torque at the output T2N [Nm]
  • at n1N

21

27

26

27

  • Maximum acceleration torque T2B [Nm]
  • Maximum 1000 cycles per hour

36

50

38

  • EMERGENCY STOP torque T2Emer [Nm]
  • Possible 1000 times during the service life of the gear unit

96

109

100

  • Nominal input speed n1N [min-1]

3300

4000

  • Maximum input speed n1Max [min-1]

7500

  • Idle torque T012 [Nm]
  • Based on the drive

0.68

0.52

0.48

0.34

0.32

Torsion and forces

  • Maximum torsional backlash jt [arcmin]

Standard ≤ 4 / Reduced ≤ 2

  • Maximum torsional rigidity Ct21 [arcmin]

3.5

  • Maximum axial force F2AMax [N]
  • In relation to the shaft center at the output

2400

  • Maximum lateral force F2QMax [N]
  • In relation to the shaft center at the output

2800

  • Maximum breakdown torque M2Max [Nm]

152

Temperature [°C]

  • Maximum housing temperature

+ 90

  • Ambient temperature

-15 to +40

Housing

  • Properties

Heat-treated steel

  • Color

Anthracite gray; RAL 7016

  • Seal

Sealed bearing discs

Mechanical data

2-stage

  • Ratio

16

20

25

28

32

35

40

50

64

70

100

  • Efficiency under full load ŋ [%]

94

  • Running noise LPA [dB]
  • at n1 = 3000 rpm without load

≤ 57

  • Service life Lh [h]

> 20000

  • Weight [kg]
  • Depending on the clamping hub diameter and selected adapter plate

2

Mass moment of inertia J1 [kgcm²]

  • Based on the drive
  • Letters = specification of the clamping hub diameter
  • B = 11 mm

0.077

0.069

0.061

0.057

0.056

  • C = 14 mm

0.17

0.16

0.15

Torques and speeds

  • Rated torque at the output T2N [Nm]
  • at n1N

38

40

38

40

31

40

31

  • Maximum acceleration torque T2B [Nm]
  • Maximum 1000 cycles per hour

50

38

50

38

  • EMERGENCY STOP torque T2Emer [Nm]
  • Possible 1000 times during the service life of the gear unit

109

100

  • Nominal input speed n1N [min-1]

4400

4800

5500

  • Maximum input speed n1Max [min-1]

8500

  • Idle torque T012 [Nm]
  • Based on the drive

0.28

0.25

0.23

0.22

0.24

0.20

0.19

0.17

0.18

Torsion and forces

  • Maximum torsional backlash jt [arcmin]

Standard ≤ 6 / Reduced ≤ 4

  • Maximum torsional rigidity Ct21 [arcmin]

3.5

  • Maximum axial force F2AMax [N]
  • In relation to the shaft center at the output

2400

  • Maximum lateral force F2QMax [N]
  • In relation to the shaft center at the output

2800

  • Maximum breakdown torque M2Max [Nm]

152

Temperature [°C]

  • Maximum housing temperature

+ 90

  • Ambient temperature

-15 to +40

Housing

  • Properties

Heat-treated steel

  • Color

Anthracite gray; RAL 7016

  • Seal

Sealed bearing discs