Technical data of the planetary gear units

Beckhoff offers planetary gears for stepper motors in order to increase the torque or to improve the mass inertia ratio. Stepper motors whose flanges have dimensions of 56 mm or above can be fitted with low-play planetary gears.

 

AG1000-+PM052.00x

AG1000-+PM081.00x

Rated torque

4 Nm

20 Nm

Acceleration torque

6 Nm

30 Nm

Gear play

≤ 0,7°

≤ 0,5°

Max. radial power

200 N

400 N

Max. axial power

60 N

80 N

Stepper motors

AS1030 and AS1050

AS1060

Fastening screws

4 x M4

4 x M6

Tightening torque

2.8 Nm

9 Nm

Operating temperature

-30 °C at + 120°C

Protection class

DIN EN 60529

Operating factor

CB = 1,0 (3h/day)

x = ratio 4 (3.7 exactly or 63/17 as a fraction), ratio 7 (6.75 exactly or 27/4 as a fraction)
Gear rim and planet wheels in steel design, straight-toothed. Lubricant Klübersynth GE14-151